$ EZ-EDS Version 3.9 Generated Electronic Data Sheet $ Rocon Delta Point EIP Electronic Data Sheet for FE18 WaterSaver $ $ Revision History: $ 1.1 07-30-2007 Initial $ 1.2 05-02-2014 Added Connection Manager Section $ 1.3 05-20-2014 Updated Packet Rates and IO sizes $ 1.4 05-19-2017 Added Assy and Param Sections, Updated Catalog and ProdName, Made RPI a Parameter $ 1.5 01-10-2020 Updated file to reflect FE18 parameters $ [File] DescText = "Rocon Delta Point Ethernet/IP EDS for FE18 WaterSaver"; CreateDate = 07-30-2007; CreateTime = 11:14:00; ModDate = 01-10-2020; ModTime = 07:05:03; Revision = 1.5; [Device] VendCode = 774; VendName = "ROCON LLC"; ProdType = 43; ProdTypeStr = "Generic Device"; ProdCode = 11; MajRev = 2; MinRev = 1; ProdName = "FE18 WaterSaver"; Catalog = "UFM/Rocon WaterSaver"; [Device Classification] Class1 = EtherNetIP; [Params] Param1 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC8, $ Data Type 4, $ Data Size in bytes "RPI Range", $ name "", $ units "", $ help string 10000,1000000,100000, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param2 = 0, $ first field shall equal 0 ,, $ path size,path 0x0002, $ descriptor (read-only, EDS internal-only) 0xC1, $ data type : BOOL 1, $ data size in bytes "OK to weld", $ name "", $ units "", $ help string 0,1,0, $ min,max,default data values ,,,, $ mult,dev,base,offset scaling not used ,,,, $ mult,dev,base,offset link not used 0; $ decimal places not used Enum2 = 0,"Fault", 1,"OK to Weld"; Param3 = 0, $ first field shall equal 0 ,, $ path size,path 0x0002, $ descriptor (read-only, EDS internal-only) 0xC1, $ data type : BOOL 1, $ data size in bytes "Valve Closed", $ name "", $ units "", $ help string 0,1,0, $ min,max,default data values ,,,, $ mult,dev,base,offset scaling not used ,,,, $ mult,dev,base,offset link not used 0; $ decimal places not used Enum3 = 0,"Open", 1,"Closed"; Param4 = 0, $ first field shall equal 0 ,, $ path size,path 0x0002, $ descriptor (read-only, EDS internal-only) 0xC1, $ data type : BOOL 1, $ data size in bytes "Valve Bypassed", $ name "", $ units "", $ help string 0,1,0, $ min,max,default data values ,,,, $ mult,dev,base,offset scaling not used ,,,, $ mult,dev,base,offset link not used 0; $ decimal places not used Enum4 = 0,"Not Bypassed", 1,"Bypassed"; Param5 = 0, $ first field shall equal 0 ,, $ path size,path 0x0002, $ descriptor (read-only, EDS internal-only) 0xC1, $ data type : BOOL 1, $ data size in bytes "Minimum Flow OK", $ name "", $ units "", $ help string 0,1,0, $ min,max,default data values ,,,, $ mult,dev,base,offset scaling not used ,,,, $ mult,dev,base,offset link not used 0; $ decimal places not used Enum5 = 0,"Below Minimum", 1,"Above Minimum"; Param6 = 0, $ first field shall equal 0 ,, $ path size,path 0x0002, $ descriptor (read-only, EDS internal-only) 0xC1, $ data type : BOOL 1, $ data size in bytes "Leak or Cap Loss", $ name "", $ units "", $ help string 0,1,0, $ min,max,default data values ,,,, $ mult,dev,base,offset scaling not used ,,,, $ mult,dev,base,offset link not used 0; $ decimal places not used Enum6 = 0,"OK", 1,"Leak or Cap Loss"; Param7 = 0, $ first field shall equal 0 ,, $ path size,path 0x0002, $ descriptor (read-only, EDS internal-only) 0xC1, $ data type : BOOL 1, $ data size in bytes "Temperature OK", $ name "", $ units "", $ help string 0,1,0, $ min,max,default data values ,,,, $ mult,dev,base,offset scaling not used ,,,, $ mult,dev,base,offset link not used 0; $ decimal places not used Enum7 = 0,"High", 1,"OK"; Param8 = 0, $ first field shall equal 0 ,, $ path size,path 0x0000, $ descriptor (read-only, EDS internal-only) 0xC6, $ data type : USINT 1, $ data size in bytes "Supply Flow", $ name "", $ units "", $ help string 0,255,0, $ min,max,default data values ,,,, $ mult,dev,base,offset scaling not used ,,,, $ mult,dev,base,offset link not used 0; $ decimal places not used Param9 = 0, $ first field shall equal 0 ,, $ path size,path 0x0000, $ descriptor (read-only, EDS internal-only) 0xC6, $ data type : USINT 1, $ data size in bytes "Return Flow", $ name "", $ units "", $ help string 0,255,0, $ min,max,default data values ,,,, $ mult,dev,base,offset scaling not used ,,,, $ mult,dev,base,offset link not used 0; $ decimal places not used Param10 = 0, $ first field shall equal 0 ,, $ path size,path 0x0000, $ descriptor (read-only, EDS internal-only) 0xC6, $ data type : USINT 1, $ data size in bytes "Temperature", $ name "", $ units "", $ help string 0,255,0, $ min,max,default data values ,,,, $ mult,dev,base,offset scaling not used ,,,, $ mult,dev,base,offset link not used 0; $ decimal places not used Param11 = 0, $ first field shall equal 0 ,, $ path size,path 0x0002, $ descriptor (read-only, EDS internal-only) 0xC1, $ data type : BOOL 1, $ data size in bytes "Run - Enable Outputs", $ name "", $ units "", $ help string 0,1,0, $ min,max,default data values ,,,, $ mult,dev,base,offset scaling not used ,,,, $ mult,dev,base,offset link not used 0; $ decimal places not used Enum11 = 0,"Outputs Disabled", 1,"Outputs Enabled"; Param12 = 0, $ first field shall equal 0 ,, $ path size,path 0x0002, $ descriptor (read-only, EDS internal-only) 0xC1, $ data type : BOOL 1, $ data size in bytes "Reset", $ name "", $ units "", $ help string 0,1,0, $ min,max,default data values ,,,, $ mult,dev,base,offset scaling not used ,,,, $ mult,dev,base,offset link not used 0; $ decimal places not used Enum12 = 0,"Reset Not Commanded", 1,"Reset Commanded"; Param13 = 0, $ first field shall equal 0 ,, $ path size,path 0x0002, $ descriptor (read-only, EDS internal-only) 0xC1, $ data type : BOOL 1, $ data size in bytes "Water Off", $ name "", $ units "", $ help string 0,1,0, $ min,max,default data values ,,,, $ mult,dev,base,offset scaling not used ,,,, $ mult,dev,base,offset link not used 0; $ decimal places not used Enum13 = 0,"Water Off Not Commanded", 1,"Water Off Commanded"; Param14 = 0, $ first field shall equal 0 ,, $ path size,path 0x0002, $ descriptor (read-only, EDS internal-only) 0xC1, $ data type : BOOL 1, $ data size in bytes "Bypass", $ name "", $ units "", $ help string 0,1,0, $ min,max,default data values ,,,, $ mult,dev,base,offset scaling not used ,,,, $ mult,dev,base,offset link not used 0; $ decimal places not used Enum14 = 0,"Bypassed Not Commanded", 1,"Bypassed Commanded"; [Assembly] Assem1 = "Inputs (T=>O), Instance 101", $ Name "20 04 24 65 30 03", $ Path , $ Size 0x0000, $ Descriptor ,, $ Reserved 16,, 1,Param2, $ 1=OK to Weld (No Fault) 1,Param3, $ 1= Valve Closed 1,Param4, $ 1= Valve Bypassed 1,Param5, $ 1=Above Minimum Flow 1,Param6, $ 1= Leak or Cap Loss 1,, $ Not used 1,Param7, $ 1=Temperature OK 1,, $ Not used 8,Param8, $ Supply Flow 8,Param9, $ Return Flow 8,Param10; $ Water Temperature Assem2 = "Outputs (O=>T), Instance 102", $ Name "20 04 24 66 30 03", $ Path , $ Size 0x0000, $ Descriptor ,, $ Reserved 1,Param11, $ 1=Run - Enable Outputs 15,, $ Not used 1,Param12, $ 1=Reset 1,Param13, $ 1= Water Off 1,Param14, $ 1= Bypass 13,; $ Not used [Connection Manager] Connection1 = 0x04010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = transport type: listen-only $ 25 = transport type: input-only $ 26 = transport type: exclusive-owner $ 27 = transport type: redundant-owner $ 28-30 = reserved $ 31 = Client = 0 / Server = 1 0x44640405, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved Param1,4,Assem2, $ O->T RPI, size, format Param1,6,Assem1, $ T->O RPI, size, format ,, $ config #1 size, format ,, $ config #2 size, format "I/O Connection", $ Connection Name "", $ help string "20 04 24 80 2C 66 2C 65"; $ Path [Port] Port1 = TCP, "Ethernet/IP Port", "20 F5 24 01", 1; [Capacity] MaxCIPConnections = 3; $ Max CIP cnx - all classes MaxConsumersPerMcast = 1; $ Max consumers per multicast cnx TSpec1 = TxRx, 2, 200; $ Packets per sec @ 2 bytes TSpec2 = TxRx, 500, 200; $ Packets per sec @ 500 bytes