Select your product options below
1/4" - 1" Vortex Shedding Flowmeter for 2 - 50 GPM Chemicals/Corrosives/Water (CX)
Select the options for your 1/4" - 1" Vortex Shedding Flowmeter for 2 - 50 GPM Chemicals/Corrosives/Water (CX) below:
Plastic Vortex Shedding Flowmeters (CX)
This owmeter is made for water, chemicals and low viscosity uids compatible with materials of construction. There are no moving parts to clog or wear. They are certified CSA and CE. They have a 4-20 mA output. There are two versions. The three wire version (power supplied separate from the 4-20) has a solid state relay that can be configured as an alarm or as a pulse out. It has a bright LED digital display of flow rate. The two wire version (option E14) has no display, pulse out or alarm point. It can be operated in an intrinsically safe mode only when used in conjunction with an approved intrinsic safety barrier meeting required entity parameters.
Flow bodies of polysulfone and Viton Seals Bluffs and Sensor made of CPVC & PVDF (standard) PEEK substituted for high temp or when desired for chemical compatability. These flowmeters have the following characteristics and/or options:
Input Power: 10 - 30 VDC @ 80 mA 3 wire stan- dard, (2 wire IS available with approved barrier but without visual readout). 35-140°F (2-66°C) standard 140-210°F (66-99°C) High temp option E20:
Electrical Connection Pin Connector (standard); Pigtails (optional)
Solid state relays as (N.O. or N.C.)
Configure one solid state relay as pulse out
Engineering units (GPM, LPM)
Flow Visual readout: 3 digit LED, 0.3" digit height Response time: 200 ms Alarm: 5% F.S. deadband Accuracy: ±1 % F.S. Repeatability: ±.25% of indicated ow Turndown (ratio of max to min ow): 10:1 (20:1 available with W1 option)
Pressure 200 PSIG (13.6 Bar) operating pressure
Fluid temperature limits: 35-140°F (2-66°C) standard 140-210°F (66-99°C) High temp option E20: (PEEK sensor and bluff)
Enclosure rating: IP65; type 4X
Pipe Connections: Female or male NPT
Minimum backpressure required (5 PSI typical at midrange, 10 PSI at high ows)
Over range to 125% without damage
Straight run 10 pipe diameters upstream and 5 down for max accuracy